  • Digital ELCB Tester

    6220 EL - Standard Electric Works Co., Ltd

    ● Microprocessor technology ensures high performance accuracy and reliability.● Fully programmable via tactile key pad.● Direct readout of disconnection, time or current.● Voltage measured during test.● Housed in a heavy duty carry case.● Suitable for all industrial, mining and domestic environments.● Display can be customized for special orders.● Indicate voltage and trip Current/Time.● Use binary principle.● True resistor switching.

  • Programmable/Direct Reading Attenuators

    ERAVANT

    Is a dual function direct reading and programmable rotary vane type attenuator for use in millimeterwave systems across the standard WR-03 frequency range of 220 to 330 GHz. The attenuator is an ideal piece of equipment in waveguide systems where a broad direct reading of attenuation is required. The default mode of operation is manual direct reading. In manual mode, the attenuation is adjustable with the large knob and the digital LCD screen displays the current attenuation value. The LCD screen is powered by an internal rechargable battery, which is charged via the 2.5mm DC jack by a provided DC to AC adapter. The 2.5mm DC jack also provides power to the stepper motor, encoder and internal microprocessor for the programmable mode function. The user can quickly switch to programmable mode by connecting the powered-up attenuator to a computer with the USB Type B port. In programmable mode, the attenuation is finely adjusted with a precision stepper motor by the internal microprocessor via user-entered serial port commands from the computer.

  • Submersible Pressure Sensors

    WIKA Alexander Wiegand SE & Co. KG

    The submersible pressure transmitter, sometimes also referred to as a level probe, is a specific design of pressure sensor for hydrostatic level measurement in tanks, wells, shafts and bore holes. For this, the submersible pressure transmitter is submerged directly in the liquid to be measured, and positioned as close as possible to the bottom. There, the submersible pressure sensor measures the hydrostatic pressure, which enables a direct conclusion regarding the current level, i.e. the height of the liquid column above it.

  • Voltmeter According to DIN EN 61010-1 (VDE 0411-1)

    PeakTech Prüf- und Messtechnik GmbH

    An innovative graphic multimeter with a 50,000-digit color TFT display for precise measurements with a high DC basic accuracy of 0.05%. The internal data logger enables the recording of measured values, which can be recorded over a period of several hours and the transfer to a Windows PC at a later time is ensured. Internally stored measured value recordings can also be accessed and graphically displayed on the multimeter itself or on the PC. Via Bluetooth, the measured values ​​can also be displayed live via app for Android and iOS devices, recorded in a table and e.g. send by email for further processing. This multimeter has a variety of measurement functions for direct and alternating voltage measurements (incl.ACV + DCV), direct and alternating current measurements, resistance, capacitance, frequency or temperature, whereby alternating voltage and alternating current are recorded as True RMS values. Due to the extensive measurement functions and the intuitive operation, this device is ideally suited for every electronics engineer, technician and engineer who attach great importance to a precise, indestructible and technically powerful multimeter.

  • NI-9247, 50 kS/s/ch, 50 Arms, 147 Apk, 24-Bit, 3-Channel C Series Current Input Module

    783589-01 - NI

    50 kS/s/ch, 50 Arms, 147 Apk, 24-Bit, 3-Channel C Series Current Input Module - The NI‑9247 is designed to support direct ring lug connectivity to the three-phase high-current measurements of 1 A and 5 A current transformers (CTs). It is optimized for power, energy, and industrial applications. The safety features, certifications, input ranges, overvoltage ranges, and connectivity are well suited for applications such as power quality monitoring and metering, utility pole-mounted smart switches, utility pole-mounted smart grid reclosers, substation merging units, industrial machine measurements, health monitoring, predictive maintenance and prognostics, and phasor measurement units (PMUs).

  • NI-9246, 50 kS/s/ch, 20 Arms, 30 Apk, 24-Bit, 3-Channel C Series Current Input Module

    783920-01 - NI

    50 kS/s/ch, 20 Arms, 30 Apk, 24-Bit, 3-Channel C Series Current Input Module - The NI‑9246 is designed to support direct ring lug connectivity to the three-phase high-current measurements of 1 A and 5 A current transformers (CTs). It is optimized for power, energy, and industrial applications. The safety features, certifications, input ranges, overvoltage ranges, and connectivity are well suited for applications such as power quality monitoring and metering, utility pole-mounted smart switches, utility pole-mounted smart grid reclosers, substation merging units, industrial machine measurements, health monitoring, predictive maintenance and prognostics, and phasor measurement units (PMUs).

  • Supercapacitor Test

    Landt Instruments, Inc

    The CT3001A/C battery test systems are upgraded from CT2001A/C with higher precision and data logging rate. The tester can be used to run precision tests for coin cells, pouch cells, prismatic cells, and especially supercapacitors (ultra-capacitors). Each tester has 8 independent channel which can be programmed to run constant current charge/discharge, constant voltage charge, constant power discharge, constant resistant discharge, and direct current internal resistance (DCIR) tests.

  • Cable Identification & Phasing

    VCi-3™ - ndb Technologies Inc.

    The VCi-3™ system is designed for cable and phase identification, mainly for instal­lation or maintenance purposes on three-phase electrical networks during power shutdowns.The transmitter module injects a low current on the cable conductors by direct con­tact or magnetic clamps methods. A voice message is recorded by the user and will be transmitted along with digital signals. Groundings stay connected at both ends of the three-phase circuit during the test. The detector module is used at the other end of the cable system.

  • Diode Laser Driver

    D200 - Highland Technology, Inc.

    The D200 is a compact, DC-coupled fast laser driver, providing up to 4 amps of regulated constant current. A built-in edge-triggered pulse generator produces up to 1 microsecond pulse widths and 2 nanosecond transition times, capable of driving lasers with forward voltages up to 9 volts. A pulse-follower mode is also provided, accommodating externally-defined trigger widths up to 100% duty continuous-wave (CW). Power, pulse width, drive current and differential triggering functions are accessible through a ribbon cable header for embedded OEM applications. A low-inductance laser drive interface permits direct laser connection or custom interposer and flex-cable attachment.

  • Electronic DC Load, 500V, 16A, 400W

    LDH400 Series - Aim-TTi

    Versatile solution for direct testing of dc power sources and PFCsConstant current, resistance, conductance and power modesWide voltage and current range, 10 to 500V and 0 to 16A400 watts continuous dissipation at 28°C (360W at 40°C)High resolution and accuracy for level settingBuilt-in transient generator with variable slewCurrent monitor output for waveform viewingVariable drop-out voltage for battery testingHigh resolution backlit graphic LCD with soft key controlAnalogue remote control of levels and TTL control of on/off and transient switchingFront and rear input terminalsLoad inputs rated to CAT II (300V)Full bus control via USB, RS232 and LXI compliant LAN interfacesGPIB Option

  • Magnetic Core Selector

    UI9702 - Lisun Electronics Inc.

    • Measure relative value of μm, Bs, Br, Hc integrated factor• No need of wiring, direct testing, being convenient• Automatic selecting, out of limit alarming, freely setting of the selecting limit• Driving current for test: 0-2A, frequency for test: 20-50kHz, both continuously adjustable, Comply with actual working situation of electronic ballast• No need of adjusting the instrument every day• Digital display, easy to read, simply and quickly to operate• Print B-H curve

  • PXI Single 8x2 1-Pole 10A Power Matrix

    40-551-002 - Pickering Interfaces Ltd.

    Used for switching inductive/capacitive loads up to 10A with 125VDC/250VAC hot switching and 400VDC/250VAC cold switching. X and Y connections are made via a 20-way GMCT plug, the 8x4 module with loop-thru has an additional 20-way GMCT plug for module-to-module connection. Power Matrix Modules are intended for switching heavy AC or DC loads or for slaving large external relays, contactors and solenoids. Suitable for applications requiring switching of either mains voltage or direct current.

  • PXI Single 8x4 1-Pole 10A Power Matrix

    40-551-001 - Pickering Interfaces Ltd.

    Used for switching inductive/capacitive loads up to 10A with 125VDC/250VAC hot switching and 400VDC/250VAC cold switching. X and Y connections are made via a 20-way GMCT plug, also available with loop-thru has an additional 20-way GMCT plug for module-to-module connection. Power Matrix Modules are intended for switching heavy AC or DC loads or for slaving large external relays, contactors and solenoids. Suitable for applications requiring switching of either mains voltage or direct current.

  • PXI Single 4x4 1-Pole 10A Power Matrix

    40-551-003 - Pickering Interfaces Ltd.

    Used for switching inductive/capacitive loads up to 10A with 125VDC/250VAC hot switching and 400VDC/250VAC cold switching. X and Y connections are made via a 20-way GMCT plug, the 8x4 module with loop-thru has an additional 20-way GMCT plug for module-to-module connection. Power Matrix Modules are intended for switching heavy AC or DC loads or for slaving large external relays, contactors and solenoids. Suitable for applications requiring switching of either mains voltage or direct current.

  • Portable Electricity Meter Testers

    EE-120A-1S - EMSYST Ltd

    The EE-120A-1S unit consists of a single-phase energy standard class 0.1 and current load up to 120A. The unit performs testing of all types single-phase electricity meters using the voltage of the site. The meter error can be measured for active, reactive or apparent energy, in Manual Mode or with predefined Test Plans using the keyboard and the LCD display on the panel. Register Test, Starting Current Test and No Load Test can be performed too. The energy standard of the system can be used without the phantom load to test meters with customer load and perform analysis of the site – with direct measurement or with optional current clamps.